Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
medRxiv ; 2024 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-38585730

RESUMO

In medication-resistant epilepsy, the objective of epilepsy surgery is to render a patient seizure free with a resection/ablation that is as small as possible to minimize morbidity. The standard of care in planning the margins of epilepsy surgery involves electroclinical delineation of the seizure onset zone (SOZ) in the epilepsy monitoring unit (EMU) by an expert epileptologist, and incorporation of neuroimaging findings from MRI, PET, SPECT, and MEG modalities. Resecting cortical tissue generating high-frequency oscillations (HFOs) has been investigated as a more efficacious alternative to targeting the SOZ. In this study, we used support vector machines (SVMs) to compare the resection volumes of actual resections, defined using the clinical standard of care, with virtual resections of fast ripple (FR 350-600 Hz) networks. Cross-validation of the SVM that labeled patients as seizure free or not seizure free using FR metrics as factors demonstrated an accuracy of 0.78. In all the patients rendered seizure free after surgery, we found that the virtual resection, defined using FR generator sites with highest rate and greatest autonomy, was larger than the actual resection. In the patients who experienced seizures after the actual resection, a virtual resection that included the SOZ and other FR generating regions rendered half of these patients virtually seizure free. We also examined patients implanted with the responsive neurostimulator system (RNS) and virtually targeted the RNS stimulation contacts proximal to sites generating FR. We used the simulations to investigate if the likelihood of a RNS super response (>90% seizure reduction) would be increased.

3.
Epilepsia ; 64(5): e48-e55, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36906958

RESUMO

How responsive neurostimulation (RNS) decreases seizure frequency is unclear. Stimulation may alter epileptic networks during inter-ictal epochs. Definitions of the epileptic network vary but fast ripples (FRs) may be an important substrate. We, therefore, examined whether stimulation of FR-generating networks differed in RNS super responders and intermediate responders. In 10 patients, with subsequent RNS placement, we detected FRs from stereo-electroencephalography (SEEG) contacts during pre-surgical evaluation. The normalized coordinates of the SEEG contacts were compared with those of the eight RNS contacts, and RNS-stimulated SEEG contacts were defined as those within 1.5 cm3 of the RNS contacts. We compared the post-RNS placement seizure outcome to (1) the ratio of stimulated SEEG contacts in the seizure-onset zone (SOZ stimulation ratio [SR]); (2) the ratio of FR events on stimulated contacts (FR SR); and (3) the global efficiency of the FR temporal correlational network on stimulated contacts (FR SGe). We found that the SOZ SR (p = .18) and FR SR (p = .06) did not differ in the RNS super responders and intermediate responders, but the FR SGe did (p = .02). In super responders, highly active desynchronous sites of the FR network were stimulated. RNS that better targets FR networks, as compared to the SOZ, may reduce epileptogenicity more.


Assuntos
Eletroencefalografia , Convulsões , Humanos
4.
Neurobiol Dis ; 177: 106000, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36638891

RESUMO

GABA is the major inhibitory neurotransmitter in the mature CNS. When GABAA receptors are activated the membrane potential is driven towards hyperpolarization due to chloride entry into the neuron. However, chloride ion dysregulation that alters the ionic gradient can result in depolarizing GABAergic post-synaptic potentials instead. In this review, we highlight that GABAergic inhibition prevents and restrains focal seizures but then reexamine this notion in the context of evidence that a static and/or a dynamic chloride ion dysregulation, that increases intracellular chloride ion concentrations, promotes epileptiform activity and seizures. To reconcile these findings, we hypothesize that epileptogenic pathologically interconnected neuron (PIN) microcircuits, representing a small minority of neurons, exhibit static chloride dysregulation and should exhibit depolarizing inhibitory post-synaptic potentials (IPSPs). We speculate that chloride ion dysregulation and PIN cluster activation may generate fast ripples and epileptiform spikes as well as initiate the hypersynchronous seizure onset pattern and microseizures. Also, we discuss the genetic, molecular, and cellular players important in chloride dysregulation which regulate epileptogenesis and initiate the low-voltage fast seizure onset pattern. We conclude that chloride dysregulation in neuronal networks appears to be critical for epileptogenesis and seizure genesis, but feed-back and feed-forward inhibitory GABAergic neurotransmission plays an important role in preventing and restraining seizures as well.


Assuntos
Cloretos , Neurônios , Humanos , Cloretos/metabolismo , Neurônios/metabolismo , Convulsões , Transmissão Sináptica/fisiologia , Receptores de GABA-A/metabolismo , Ácido gama-Aminobutírico
5.
Clin Neurophysiol ; 129(10): 2089-2098, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30077870

RESUMO

OBJECTIVE: To test the utility of a novel semi-automated method for detecting, validating, and quantifying high-frequency oscillations (HFOs): ripples (80-200 Hz) and fast ripples (200-600 Hz) in intra-operative electrocorticography (ECoG) recordings. METHODS: Sixteen adult patients with temporal lobe epilepsy (TLE) had intra-operative ECoG recordings at the time of resection. The computer-annotated ECoG recordings were visually inspected and false positive detections were removed. We retrospectively determined the sensitivity, specificity, positive and negative predictive value (PPV/NPV) of HFO detections in unresected regions for determining post-operative seizure outcome. RESULTS: Visual validation revealed that 2.81% of ripple and 43.68% of fast ripple detections were false positive. Inter-reader agreement for false positive fast ripple on spike classification was good (ICC = 0.713, 95% CI: 0.632-0.779). After removing false positive detections, the PPV of a single fast ripple on spike in an unresected electrode site for post-operative non-seizure free outcome was 85.7 [50-100%]. Including false positive detections reduced the PPV to 64.2 [57.8-69.83%]. CONCLUSIONS: Applying automated HFO methods to intraoperative electrocorticography recordings results in false positive fast ripple detections. True fast ripples on spikes are rare, but predict non-seizure free post-operative outcome if found in an unresected site. SIGNIFICANCE: Semi-automated HFO detection methods are required to accurately identify fast ripple events in intra-operative ECoG recordings.


Assuntos
Eletrocorticografia/métodos , Epilepsia/cirurgia , Monitorização Neurofisiológica Intraoperatória/métodos , Adolescente , Adulto , Ondas Encefálicas , Eletrocorticografia/instrumentação , Epilepsia/fisiopatologia , Feminino , Humanos , Monitorização Neurofisiológica Intraoperatória/instrumentação , Masculino , Pessoa de Meia-Idade
6.
7.
F1000Res ; 6: 30, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28491280

RESUMO

Objective: To develop a novel software method (AR2) for reducing muscle contamination of ictal scalp electroencephalogram (EEG), and validate this method on the basis of its performance in comparison to a commercially available software method (AR1) to accurately depict seizure-onset location. Methods: A blinded investigation used 23 EEG recordings of seizures from 8 patients. Each recording was uninterpretable with digital filtering because of muscle artifact and processed using AR1 and AR2 and reviewed by 26 EEG specialists. EEG readers assessed seizure-onset time, lateralization, and region, and specified confidence for each determination. The two methods were validated on the basis of the number of readers able to render assignments, confidence, the intra-class correlation (ICC), and agreement with other clinical findings. Results: Among the 23 seizures, two-thirds of the readers were able to delineate seizure-onset time in 10 of 23 using AR1, and 15 of 23 using AR2 (p<0.01). Fewer readers could lateralize seizure-onset (p<0.05). The confidence measures of the assignments were low (probable-unlikely), but increased using AR2 (p<0.05). The ICC for identifying the time of seizure-onset was 0.15 (95% confidence interval (CI), 0.11-0.18) using AR1 and 0.26 (95% CI 0.21-0.30) using AR2.  The EEG interpretations were often consistent with behavioral, neurophysiological, and neuro-radiological findings, with left sided assignments correct in 95.9% (CI 85.7-98.9%, n=4) of cases using AR2, and 91.9% (77.0-97.5%) (n=4) of cases using AR1. Conclusions: EEG artifact reduction methods for localizing seizure-onset does not result in high rates of interpretability, reader confidence, and inter-reader agreement. However, the assignments by groups of readers are often congruent with other clinical data. Utilization of the AR2 software method may improve the validity of ictal EEG artifact reduction.

8.
Epilepsia ; 57(1): 111-21, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26611159

RESUMO

OBJECTIVE: To characterize local field potentials, high frequency oscillations, and single unit firing patterns in microelectrode recordings of human limbic onset seizures. METHODS: Wide bandwidth local field potential recordings were acquired from microelectrodes implanted in mesial temporal structures during spontaneous seizures from six patients with mesial temporal lobe epilepsy. RESULTS: In the seizure onset zone, distinct epileptiform discharges were evident in the local field potential prior to the time of seizure onset in the intracranial EEG. In all three seizures with hypersynchronous (HYP) seizure onset, fast ripples with incrementally increasing power accompanied epileptiform discharges during the transition to the ictal state (p < 0.01). In a single low voltage fast (LVF) onset seizure a triad of evolving HYP LFP discharges, increased single unit activity, and fast ripples of incrementally increasing power were identified ~20 s prior to seizure onset (p < 0.01). In addition, incrementally increasing fast ripples occurred after seizure onset just prior to the transition to LVF activity (p < 0.01). HYP onset was associated with an increase in fast ripple and ripple rate (p < 0.05) and commonly each HYP discharge had a superimposed ripple followed by a fast ripple. Putative excitatory and inhibitory single units could be distinguished during limbic seizure onset, and heterogeneous shifts in firing rate were observed during LVF activity. SIGNIFICANCE: Epileptiform activity is detected by microelectrodes before it is detected by depth macroelectrodes, and the one clinically identified LVF ictal onset was a HYP onset at the local level. Patterns of incrementally increasing fast ripple power are consistent with observations in rats with experimental hippocampal epilepsy, suggesting that limbic seizures arise when small clusters of synchronously bursting neurons increase in size, coalesce, and reach a critical mass for propagation.


Assuntos
Potenciais de Ação/fisiologia , Ondas Encefálicas/fisiologia , Córtex Entorrinal/patologia , Epilepsia do Lobo Temporal/patologia , Epilepsia do Lobo Temporal/fisiopatologia , Adulto , Relógios Biológicos/fisiologia , Eletroencefalografia , Feminino , Análise de Fourier , Humanos , Masculino , Microeletrodos , Pessoa de Meia-Idade , Estudos Retrospectivos
9.
Front Hum Neurosci ; 5: 81, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21887140

RESUMO

Cognitive remediation involves task practice and may improve deficits in people suffering from schizophrenia, but little is known about underlying neurophysiological mechanisms. In people with schizophrenia and controls, we used magnetoencephalography (MEG) to examine accuracy and practice-related changes in parameters indexing neural network structure and activity, to determine whether these might be useful assays of the efficacy of cognitive remediation. Two MEG recordings were acquired during performance of a tone discrimination task used to improve the acuity of auditory processing, before and after ∼2.5 h of task practice. Accuracy before practice was negatively correlated with beta-band cost efficiency, a graph theoretical measure of network organization. Synthetic aperture magnetometry was used to localize brain oscillations with high spatial accuracy; results demonstrated sound and sensorimotor modulations of the beta band in temporo-parietal regions and the sensorimotor cortex respectively. High-gamma activity also correlated with sensorimotor processing during the task, with activation of auditory regions following sound stimulation, and activation of the left sensorimotor cortex preceding the button press. High-gamma power in the left frontal cortex was also found to correlate with accuracy. Following practice, sound-induced broad-band power in the left angular gyri increased. Accuracy improved and was found to correlate with increased mutual information (MI) between sensors in temporal-parietal regions in the beta band but not global cost efficiency. Based on these results, we conclude that hours of task practice can induce meso-scale changes such as increased power in relevant brain regions as well as changes in MI that correlate with improved accuracy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA